The Best Guide to Run Capacitor

ⅠIntroduction

Motor capacitors temporarily store an electrical charge to provide additional torque and improve the performance and efficiency of a motor. Start capacitors provide added torque during motor startup and then exit the circuit when the motor reaches operating speed. Run capacitors assist the motor in maintaining a consistent charge while it is running. By balancing working power and supplied power, power factor correction capacitors reduce motor power consumption caused by heavy inductive loads. Motor capacitors are most frequently used to power motors in HVAC applications such as fans, blowers, and compressors, but they are also found in pumps, conveyors, and machine tools.

What-does-a-run-capacitor-look-like?

What does a run capacitor look like?

Catalog

ⅠIntroduction

Ⅱ Two Types of Motor Capacitor

2.1 What is the run capacitor?

2.2 What is the starter capacitor?

Ⅲ Run Capacitor Related Video

Ⅳ Specifications of Run Capacitor

Ⅴ Faulty Run Capacitor

5.1 When Is It Time to Replace a Run Capacitor?

5.2 Causes of Failure

Ⅵ How To Replace a Start Run Capacitor?

Ⅶ How Do They Work In an HVAC System?

Ⅷ Dual Capacitors vs. Run Capacitors vs. Run Capacitors

Ⅸ FAQ

Ⅱ Two Types of Motor Capacitor

Motor capacitor include two types: run capacitor and starter capacitor. Let us have a look at the two capacitors.

2.1 What is the run capacitor?

Run capacitors are rated in the 3–70 microfarad range (uF). Voltage classification is also applied to rate run capacitors. The voltage levels are 370V and 440V. Starting capacitors have ratings greater than 70 microfarads (uF). Run capacitors are designed for continuous duty and remain energized throughout the lasting of the motor's operation. A capacitor is required to power a second phase winding in a single-phase electric motor. This is why the sizing is so crucial. The motor will not have an even magnetic field if the incorrect run capacitor is installed.This case will lead to the rotor hesitating at uneven spots. This pause causes the motor to become noisy, increases energy consumption, reduces performance, and causes the motor to overheat.

2.2 What is the starter capacitor?

In contrast to run capacitors, which have a specific uF rating, starting capacitors are housed in a black plastic case and have an uF range. Start capacitors (with ratings of 70 microfarads or higher) are classified into three voltage classes: 125V, 250V, and 330V. A 35 uF at 370V run capacitor and an 88–108 uF at 250V start capacitor are two examples. Start capacitors increase motor starting torque and allow a motor to be rapidly cycled on and off. Start capacitors are designed for one-time use only. Start capacitors are energized for a short time, allowing the motor to reach 3/4 of its full speed before being disconnected from the circuit.

Ⅲ Run Capacitor Related Video

Start Capacitors & Run Capacitors for Electric Motors - Differences Explained by TEMCo

run capacitor video descriped:  What's the difference between a start capacitor and a run capacitor? Can you use them interchangeably? See why these two types of capacitors cannot always be substituted for one another.

Ⅳ Specifications of Run Capacitor

Most run capacitor applications employ capacitance ratings of 2.5-100 uf (microfarads) and voltages of 370 or 440 VAC. They are also usually rated at 50 and 60 Hz. Cases are typically round or oval in shape, with a steel or aluminum shell and cap. Terminals are typically 14" push-on terminals with 2-4 terminals per connection post.

  • Voltage: Choose a capacitor with a voltage rating equal to or higher than the original capacitor. If you have a 370-volt capacitor, either a 370 or a 440-volt capacitor will work, though the 440-volt unit will last longer. A run capacitor will have a marked voltage indicating the acceptable peak voltage - not the operational voltage.

  • Capacitance: It is better to choose a capacitor with the same capacitance value (measured in MFD, uf, or microfarad) as the original capacitor. Do not break away the original value, as it determines the motor's operational characteristics.
  • Hz : A run capacitor marked 50/60 is the best choice as it has the same Hz rating as the original.  
  • Case Style: Oval or round? Although round run capacitors are by far more common than any other capacitors, oval designs are still applied in many motors. Electrically, there is no distinction. The only question here is fit. The case style is unimportant if space in the mounting box is not limited.
  • Overall Size: Just like case style, overall size has no electrical significance. Choose a capacitor that will fit in the available space.
  • Terminal Type: The majority of run capacitor terminal designs include 1-4 14" push on tabs with 3 or 4 tabs. Merely ensure that you have enough tabs per connection post to make the necessary connections.

 Specifications-of Run-Capacitor

Specifications of Run Capacitor

Ⅴ Faulty Run Capacitor

5.1 When Is It Time to Replace a Run Capacitor?

As a general rule, a run capacitor will greatly exceed the start capacitor of the same motor. A run motor capacitor will wear down at different levels, making it more complicated to determine if it needs to be replaced.

When a run capacitor begins to perform outside of its allowable range, the rated capacitance value usually drops. A "tolerance" will be specified for most standard motor run capacitors, describing how close the actual value may be to the rated capacitance value. It is usually within +/- 5% to 10%. For most motors, as long as the actual value is within 10% of the rated value, you're good to go.

A run capacitor will occasionally bulge from internal pressure due to a flaw in the capacitor's construction or a non-capacitor-related motor issue. Most modern run capacitor designs will open the circuit, disconnecting the internal spiral membrane as a precautionary measure to keep the capacitor from popping.

The test is simple: it is time to replace in both cases that it is  bulging and there is  no continuity between the terminals,

Run-Capacitor

Run Capacitor

5.2 Causes of Failure

Depending on how close the run capacitor is to its design life, there could be several reasons why it failed.

  • Time - All capacitors are designed to last a certain amount of time. Several factors can be swapped or combined to control the life of a run capacitor, but once the design life is exceeded, the internals may begin to decay more quickly and perform worse. Simply put, a failure could happen because the capacitor is "just old."

  • Heat - If the operating temperature is higher than the design limit, it can have a significant impact on run capacitor life expectancy. In general, motors operated in hot environments or with little ventilation have a significantly reduced run capacitor lifespan. Radiated heat from a generally hot running motor can also give rise to the capacitor to overheat. Your run capacitor will last much longer with cooling situation.
  • Current - When the motor fails, the capacitor becomes overloaded. This scenario is uncommon because it is usually accompanied by a partial or complete motor failure. The motor is overloaded or has a windings failure, causing the current to rise. It has the potential to affect the capacitor.
  • Voltage - This single factor has the potential to have an exponential effect on design life. A run capacitor has a voltage rating that should be limited. As an example, consider 440 volts. The life may be down by 20% at 450 volts. At 460 volts, the life may be reduced by half. At 470 volts, the life is reduced by 75%, and so on. The same principle is suitable in reverse to help extend life by using a capacitor with a voltage rating significantly higher than required, albeit to a lesser extent.

Diagnosing and Replacing a Run Capacitor

Ⅵ How To Replace a Start Run Capacitor?

When a new motor is installed, a new fan capacitor should always be installed. It is always a good idea to photograph or write down the wire coloring and connections.

  • Turn off the power to the HVAC unit and use a meter to ensure it is completely off.

  • Locate and remove the side panel where the electricity is fed into the unit.
  • Locate the Stat Run Capacitor;  there will only be one in a Dual Run capacitor. If there are two, only the fan motor capacitor has to be replaced.
  • Check the MFD and voltages, then connect the new connections from the old capacitor to the new capacitor one leg at a time to ensure they are correct.

(For example, if you have two capacitors, one is for the compressor and the other is for the fan motor.)

Ⅶ How Do They Work In an HVAC System?

A Start or Run Capacitor can be combined into a single capacitor with three leads known as a Dual Capacitor, or it can be split between two separate capacitors.

The Start Capacitor gives a fan motor the torque it needs to start spinning and then turns off, whereas the Run Capacitor stays on and provides extra torque to the motor when needed.

The motor will most likely not start if the Start Capacitor fails. If a Run capacitor fails, the motor will start, but the running amperage will be higher than usual, causing the motor to run hot and have a short life expectancy.

There are three connections on a Dual Capacitor: HERM, FAN, and COM.

HERM is for the Hermetically Sealed Compressor, FAN is for the Condenser Fan Motor, and COM is for the Contactor, which powers the Capacitor.

If the unit has two capacitors, the larger of the two is the Run Capacitor. Keep in mind that the compressor frequently necessitates the use of a HERM capacitor (compressor).

Run Capacitor circuit

Ⅷ Dual Capacitors vs. Run Capacitors vs. Run Capacitors

The only benefit we can get from the dual-run capacitor design is that it comes in a small package with only three connections. Aside from that, there is no distinction between run and dual run capacitors. If there is enough space for mounting, it is acceptable to replace your original dual-run capacitor with two separate run capacitors. They typically have "C" connections for "common," "H" or "Herm" connections for "Hermetic Compressor," and "F" connections for "Fan." They'll also have two different capacitor ratings for the two parts.

Start capacitors provide a high capacitance value required for motor starting in a very short (seconds) time. They are only designed for intermittent duty and will fail catastrophically if left on for an extended time. Run capacitors are continuous duty because they provide continuous voltage and current control to a motor's windings. They typically have a much lower capacitance value.

Ⅸ FAQ

1. What happens when a run capacitor goes bad?

A bad motor capacitor may cause starting problems or could shut off the motor while running. Same principle on the dirty coil. ... If a Run capacitor goes bad then a motor can turn on but the running amperage will be higher than normal causing the motor to run hot and have a short life expectancy.

2. What is the difference between a capacitor and a run capacitor?

The start capacitor creates a current to voltage lag in the separate start windings of the motor. The current builds up slowly, and the armature has an opportunity to begin rotating with the field of current. A run capacitor uses the charge in the dielectric to boost the current which provides power to the motor.

3. Can I run my AC without a capacitor?

Most of the motors in your air conditioner can't run without a good capacitor. Like I said, they support these motors. They help the motor start and run efficiently. Some people have gone out to their air conditioner and noticed the fan wasn't spinning on their AC as it should be.

4. Can I use a run capacitor in place of a start capacitor?

The capacitance and voltage ratings would have to match the original start capacitor specification. A start capacitor can never be used as a run capacitor, because it cannot not handle current continuously.

5. Do I need a start or run capacitor?

Run capacitors are designed for continuous duty, and are energized the entire time the motor is running. Single phase electric motors need a capacitor to energize a second phase winding. ... Start capacitors increase motor starting torque and allow a motor to be cycled on and off rapidly.

6. What size run capacitor do I need?

The run capacitor should have the exact microfarad (uf) that the motor is rated for. Capacitors rated above 70uf are considered Start Capacitors and are generally removed from the circuit electrically during operation. This is where the rule of +/- 10% of the rating came from, for Start Capacitors ONLY!